Thermaster
Thermaster TS1500BT Double Door Workbench Freezer 283L | 600 Series Stainless Steel 10A
[THERMASTER_MSG]
Combine a durable food preparation worktop with commercial sub-zero storage using the Thermaster TS1200BT 205L Commercial Stainless Steel Double Door Workbench Freezer. Purpose-built for Australian restaurants, cafes, burger outlets, pizzerias, bakeries, and commercial catering passes where cookline space is tight, this compact 600 Series underbench freezer pairs an 850 mm working height stainless steel prep bench with a 205-litre two-door sub-zero cabinet to keep frozen ingredients right at the chef's station.
Maintaining strict sub-zero temperatures is essential for preserving pre-portioned burger patties, frozen seafood, chips, poultry, and pastry bases. The TS1200BT operates reliably across a -18°C to -22°C range, keeping food solidly frozen and fully compliant with Australian food safety standards. To prevent perimeter condensation in humid commercial environments, the cabinet is engineered with an integrated heated door frame, eliminating moisture build-up around the magnetic door gaskets and stopping doors from freezing shut.
Driven by an efficient commercial refrigeration package, the unit utilises fan-forced evaporator convection airflow to circulate sub-zero air evenly throughout the interior cavity. This dynamic circulation prevents internal warm zones and ensures rapid temperature recovery after frequent service openings. Rated for dependable commercial operation in ambient room temperatures up to 32°C, the TS1200BT features an automatic cycle defrost system paired with a self-evaporating condensate pan, eliminating manual ice scraping and external drainage plumbing.
Measuring 1200 mm wide by a compact 600 mm deep, the 600 Series footprint integrates neatly into busy cooklines, back-bar runs, and pass counters without obstructing tight kitchen walkways. The reinforced solid stainless steel top deck functions as a durable prep bench for chopping boards, food pans, or countertop appliances. High-density,100% CFC- and HCFC-free polyurethane insulation ensures superior thermal retention and prevents cabinet sweating.
Fabricated from high-grade commercial food-grade stainless steel inside and out, the TS1200BT resists corrosive food acids, kitchen grease, and regular commercial sanitising agents. The internal storage cavity features coved, rounded internal corners that eliminate dirt traps, ensuring fast, hygienic end-of-shift wipe-downs. Factory-fitted heavy-duty swivel castors allow kitchen staff to roll the 85 kg unit smoothly for thorough under-bench floor cleaning and layout adjustments.
Operating on single-phase 240V power with an economical 520W power draw (approx. 2.2 Amps) and consuming 6.755 kWh per 24 hours, the TS1200BT connects straight into any standard Australian 10 Amp commercial wall outlet without requiring three-phase wiring. Supported by an extended 2+2 Year Commercial Warranty, it provides dependable long-term performance and peace of mind.
Sub-Zero -18°C to -22°C Storage Range: Maintains optimal holding temperatures for frozen meats, poultry, seafood, chips, and pre-prepped kitchen stock.
Integrated Heated Door Frame: Prevents condensation and ice formation along the door jamb, stopping gaskets from freezing shut in humid kitchens.
Durable 1200 mm Solid Stainless Steel Worktop: Serves as a primary food prep surface at an ergonomic 850 mm working height.
Space-Saving 600 Series Profile (1200 mm W x 600 mm D): Practical slimline depth fits into compact prep lines and underbench cooking suites.
205L Gross Storage Volume (161L Net): Two solid door compartments provide practical undercounter frozen capacity right at the cookline.
Dynamic Fan-Forced Evaporator Cooling: Actively circulates sub-zero air to eliminate thermal stratification and recover temperature rapidly after door openings.
Zero-Plumbing Condensate Evaporation: Automatic cycle defrost with an internal heated pan evaporates meltwater without requiring floor waste plumbing.
Hygienic Coved Interior Corners: Smooth, rounded internal cabinet transitions eliminate food traps for rapid wipe-down sanitation.
Eco-Friendly CFC- & HCFC-Free Insulation: High-density polyurethane foam locks in cold air and dampens compressor cycling.
Heavy-Duty Swivel Castors Fitted: Ensures effortless mobility for under-bench floor cleaning, preventative maintenance, and kitchen repositioning.
Standard Australian 10A Plug Setup: Low 520W power consumption connects straight into standard 240V single-phase commercial power points.
Extended 2+2 Year Warranty: Standard 2 Years Parts and Labour warranty, extendable by an additional 2 Years (Parts only) upon online product registration within 14 days of invoice.
| Feature | Specification Details |
| Model Code / SKU | TS1200BT |
| Brand | Thermaster |
| Product Series | 600 Series Commercial Workbench Refrigeration |
| Product Type | Commercial Double Solid Door Workbench Storage Freezer |
| Gross Storage Volume | 205 Litres |
| Net Storage Volume | 161 Litres |
| Operating Temperature Range | -18°C to -22°C |
| Condensation Control | Heated Door Frame Assembly |
| Daily Energy Consumption | 6.755 kWh / 24 Hours |
| Ambient Climate Rating | Tested up to 32°C Max Ambient Temperature |
| Cooling Mechanism | Fan-Forced Evaporator Convection Airflow |
| Defrost & Drainage | Fully Automatic Cycle Defrost with Self-Evaporating Condensate Pan |
| Insulation | High-Density Polyurethane Foam (100% CFC & HCFC Free) |
| Door Assembly | 2 x Heavy-Duty Hinged Solid Stainless Steel Doors (Self-Closing) |
| Internal Cavity Finish | Food-Grade Stainless Steel with Rounded Coved Corners |
| Chassis & Exterior Finish | Commercial Food-Grade Stainless Steel |
| Mobility | Heavy-Duty Swivel Castors Fitted as Standard |
| External Dimensions | 850(H) x 1200(W) x 600(D) mm |
| Net Weight | 85.0 kg |
| Electrical Power | 240V / 50Hz / Single Phase (520W / Standard AU 10A Plug & Lead) |
| Warranty | 2 Years Parts & Labour + 2 Years Parts-Only with Product Registration within 14 Days of Invoice |
To protect refrigeration efficiency, prevent compressor strain, and ensure commercial hygiene compliance:
Power Isolation: Before undertaking deep interior cleaning or rearranging internal wire shelving tiers, isolate the unit at the power point and disconnect the plug from the 10A wall outlet.
Stainless Steel Benchtop & Exterior Care: Wipe down the 1200 mm stainless steel prep deck, door faces, handles, and side panels daily using warm water and a neutral commercial sanitiser. Dry thoroughly with a clean microfibre cloth following the grain of the steel. Never use steel wool, wire brushes, metal scrapers, or chlorine bleach, as these will scratch the surface and induce pitting.
Internal Cabinet Sanitisation: Remove the internal wire shelving and wipe down the coved stainless steel interior walls and floor deck. Wipe down the perimeter magnetic door gaskets with warm, mild soapy water to remove accumulated food oils and crumbs, ensuring an airtight seal.
Condenser Coil Dusting (Crucial for Energy Efficiency): Unplug the unit and inspect the compressor ventilation compartment monthly. Airborne kitchen grease and dust accumulate on the condenser fins, restricting airflow and forcing the compressor to run hotter and consume excess electricity. Vacuum or gently brush the condenser fins with a soft brush attachment at least once a month.
Ventilation Clearances: Maintain at least 100 mm of clearance from the wall around all ventilation grilles to allow hot exhaust air to escape freely.
Drainage Clearance: Check the internal condensate drain channel during routine cleaning to ensure it remains clear of loose packaging labels, plastic film, and food crumbs.
Electrical Safety: Never wash down the workbench freezer with a commercial pre-rinse hose or high-pressure spray gun, and ensure water does not enter the digital controller or rear ventilation louvres.
The Thermaster TS1200BT is engineered for commercial prep lines, cafe counters, and underbench cookline spaces:
Standard 10A Electrical Connection: The workbench freezer draws 520W on standard single-phase 240V power and comes fitted with a standard Australian 10 Amp plug. Connect directly into a dedicated commercial wall outlet. Avoid the use of domestic extension leads or double adaptors.
Solid Floor Positioning & Stability: Position the 85 kg unit (exceeding 200 kg when fully loaded) on a flat, level, and solid commercial floor. Once rolled into place, ensure the castors sit evenly to prevent cabinet rocking and ensure both doors seal squarely.
Mandatory 100 mm Wall Ventilation Clearance: A minimum 100 mm wall clearance is strictly required around the ventilation louvres to ensure adequate heat dissipation from the compressor compartment. Restricting this airflow will reduce cooling performance, increase electricity consumption, and risk premature compressor failure.
Thermal Separation & Direct Heat: While rated for 32°C ambient conditions, avoid positioning the workbench freezer directly adjacent to intense heat-generating cooking equipment (such as deep fryers, open charbroilers, or high-temperature ranges) without a thermal heat barrier. Radiant heat warms the cabinet exterior and forces the refrigeration system to cycle continuously.
Pre-Freezing Protocol (Standard 3.2.2 Compliance): In accordance with Australian Commercial Food Safety Standards, underbench freezers are holding units designed to maintain pre-frozen product temperatures (-18°C to -22°C).All meats, seafood, chips, and ingredients must be pre-frozen below -18°C before loading into the cabinet. Never use the cabinet to freeze down hot, warm, or room-temperature foods.
Standard commercial road freight delivery is available Australia-wide to commercial business addresses with level ground access or loading docks. Due to the 85 kg net weight and commercial crating of this stainless steel workbench freezer, tail-lift delivery or a commercial loading dock with pallet handling equipment is recommended. For deliveries to residential or non-commercial addresses, please contact our friendly commercial sales team prior to ordering to obtain a customised courier quote and confirm delivery logistics.
Can I plug this double door workbench freezer into a standard Australian 10 Amp power point?
Yes. The Thermaster TS1200BT draws 520W on standard single-phase 240V power and comes fitted with a standard Australian 10 Amp plug. It connects straight into standard commercial wall sockets with no specialized electrical wiring required.
What is the difference between the TS1200TN and TS1200BT models?
The TS1200TN is a commercial workbench refrigerator operating between -2°C and +8°C for fresh ingredients. The TS1200BT is a commercial workbench freezer operating between -18°C and -22°C for frozen food storage, featuring higher wattage (520W) and an integrated heated door frame to eliminate frame frost and condensation.
Why does this freezer have a heated door frame?
Because the cabinet runs at sub-zero temperatures (-18°C to -22°C), contact with humid kitchen air causes condensation and frost around the door perimeter. The heated frame prevents this moisture accumulation, ensuring the magnetic rubber gaskets seal tightly and doors do not freeze shut.
Why is 100 mm of wall clearance required?
Commercial refrigeration compressors generate heat while extracting warm air from the cabinet interior. Maintaining at least 100 mm of clearance from the rear and side ventilation louvres allows this heat to dissipate efficiently into the room. Blocking these vents causes the compressor to overheat, reducing cooling performance and voiding the warranty.
Can I use the stainless steel top as a direct food preparation surface?
Yes. The solid stainless steel worktop is reinforced for commercial food preparation, allowing staff to place chopping boards, assemble orders, or mount benchtop appliances like slicers or vacuum sealers directly on top.
How do I qualify for the extended 2+2 Year Warranty?
The unit comes standard with a 2 Years Commercial Parts and Labour warranty. By registering your product online with the manufacturer within 14 days of the invoice date, you receive an additional 2 Years of Parts-Only warranty coverage, securing four total years of manufacturer protection.
N.B Image is for illustrative purposes only. Specifications are subject to change without notice.
[THERMASTER_MSG]
Combine a durable food preparation worktop with commercial sub-zero storage using the Thermaster TS1200BT 205L Commercial Stainless Steel Double Door Workbench Freezer. Purpose-built for Australian restaurants, cafes, burger outlets, pizzerias, bakeries, and commercial catering passes where cookline space is tight, this compact 600 Series underbench freezer pairs an 850 mm working height stainless steel prep bench with a 205-litre two-door sub-zero cabinet to keep frozen ingredients right at the chef's station.
Maintaining strict sub-zero temperatures is essential for preserving pre-portioned burger patties, frozen seafood, chips, poultry, and pastry bases. The TS1200BT operates reliably across a -18°C to -22°C range, keeping food solidly frozen and fully compliant with Australian food safety standards. To prevent perimeter condensation in humid commercial environments, the cabinet is engineered with an integrated heated door frame, eliminating moisture build-up around the magnetic door gaskets and stopping doors from freezing shut.
Driven by an efficient commercial refrigeration package, the unit utilises fan-forced evaporator convection airflow to circulate sub-zero air evenly throughout the interior cavity. This dynamic circulation prevents internal warm zones and ensures rapid temperature recovery after frequent service openings. Rated for dependable commercial operation in ambient room temperatures up to 32°C, the TS1200BT features an automatic cycle defrost system paired with a self-evaporating condensate pan, eliminating manual ice scraping and external drainage plumbing.
Measuring 1200 mm wide by a compact 600 mm deep, the 600 Series footprint integrates neatly into busy cooklines, back-bar runs, and pass counters without obstructing tight kitchen walkways. The reinforced solid stainless steel top deck functions as a durable prep bench for chopping boards, food pans, or countertop appliances. High-density,100% CFC- and HCFC-free polyurethane insulation ensures superior thermal retention and prevents cabinet sweating.
Fabricated from high-grade commercial food-grade stainless steel inside and out, the TS1200BT resists corrosive food acids, kitchen grease, and regular commercial sanitising agents. The internal storage cavity features coved, rounded internal corners that eliminate dirt traps, ensuring fast, hygienic end-of-shift wipe-downs. Factory-fitted heavy-duty swivel castors allow kitchen staff to roll the 85 kg unit smoothly for thorough under-bench floor cleaning and layout adjustments.
Operating on single-phase 240V power with an economical 520W power draw (approx. 2.2 Amps) and consuming 6.755 kWh per 24 hours, the TS1200BT connects straight into any standard Australian 10 Amp commercial wall outlet without requiring three-phase wiring. Supported by an extended 2+2 Year Commercial Warranty, it provides dependable long-term performance and peace of mind.
Sub-Zero -18°C to -22°C Storage Range: Maintains optimal holding temperatures for frozen meats, poultry, seafood, chips, and pre-prepped kitchen stock.
Integrated Heated Door Frame: Prevents condensation and ice formation along the door jamb, stopping gaskets from freezing shut in humid kitchens.
Durable 1200 mm Solid Stainless Steel Worktop: Serves as a primary food prep surface at an ergonomic 850 mm working height.
Space-Saving 600 Series Profile (1200 mm W x 600 mm D): Practical slimline depth fits into compact prep lines and underbench cooking suites.
205L Gross Storage Volume (161L Net): Two solid door compartments provide practical undercounter frozen capacity right at the cookline.
Dynamic Fan-Forced Evaporator Cooling: Actively circulates sub-zero air to eliminate thermal stratification and recover temperature rapidly after door openings.
Zero-Plumbing Condensate Evaporation: Automatic cycle defrost with an internal heated pan evaporates meltwater without requiring floor waste plumbing.
Hygienic Coved Interior Corners: Smooth, rounded internal cabinet transitions eliminate food traps for rapid wipe-down sanitation.
Eco-Friendly CFC- & HCFC-Free Insulation: High-density polyurethane foam locks in cold air and dampens compressor cycling.
Heavy-Duty Swivel Castors Fitted: Ensures effortless mobility for under-bench floor cleaning, preventative maintenance, and kitchen repositioning.
Standard Australian 10A Plug Setup: Low 520W power consumption connects straight into standard 240V single-phase commercial power points.
Extended 2+2 Year Warranty: Standard 2 Years Parts and Labour warranty, extendable by an additional 2 Years (Parts only) upon online product registration within 14 days of invoice.
| Feature | Specification Details |
| Model Code / SKU | TS1200BT |
| Brand | Thermaster |
| Product Series | 600 Series Commercial Workbench Refrigeration |
| Product Type | Commercial Double Solid Door Workbench Storage Freezer |
| Gross Storage Volume | 205 Litres |
| Net Storage Volume | 161 Litres |
| Operating Temperature Range | -18°C to -22°C |
| Condensation Control | Heated Door Frame Assembly |
| Daily Energy Consumption | 6.755 kWh / 24 Hours |
| Ambient Climate Rating | Tested up to 32°C Max Ambient Temperature |
| Cooling Mechanism | Fan-Forced Evaporator Convection Airflow |
| Defrost & Drainage | Fully Automatic Cycle Defrost with Self-Evaporating Condensate Pan |
| Insulation | High-Density Polyurethane Foam (100% CFC & HCFC Free) |
| Door Assembly | 2 x Heavy-Duty Hinged Solid Stainless Steel Doors (Self-Closing) |
| Internal Cavity Finish | Food-Grade Stainless Steel with Rounded Coved Corners |
| Chassis & Exterior Finish | Commercial Food-Grade Stainless Steel |
| Mobility | Heavy-Duty Swivel Castors Fitted as Standard |
| External Dimensions | 850(H) x 1200(W) x 600(D) mm |
| Net Weight | 85.0 kg |
| Electrical Power | 240V / 50Hz / Single Phase (520W / Standard AU 10A Plug & Lead) |
| Warranty | 2 Years Parts & Labour + 2 Years Parts-Only with Product Registration within 14 Days of Invoice |
To protect refrigeration efficiency, prevent compressor strain, and ensure commercial hygiene compliance:
Power Isolation: Before undertaking deep interior cleaning or rearranging internal wire shelving tiers, isolate the unit at the power point and disconnect the plug from the 10A wall outlet.
Stainless Steel Benchtop & Exterior Care: Wipe down the 1200 mm stainless steel prep deck, door faces, handles, and side panels daily using warm water and a neutral commercial sanitiser. Dry thoroughly with a clean microfibre cloth following the grain of the steel. Never use steel wool, wire brushes, metal scrapers, or chlorine bleach, as these will scratch the surface and induce pitting.
Internal Cabinet Sanitisation: Remove the internal wire shelving and wipe down the coved stainless steel interior walls and floor deck. Wipe down the perimeter magnetic door gaskets with warm, mild soapy water to remove accumulated food oils and crumbs, ensuring an airtight seal.
Condenser Coil Dusting (Crucial for Energy Efficiency): Unplug the unit and inspect the compressor ventilation compartment monthly. Airborne kitchen grease and dust accumulate on the condenser fins, restricting airflow and forcing the compressor to run hotter and consume excess electricity. Vacuum or gently brush the condenser fins with a soft brush attachment at least once a month.
Ventilation Clearances: Maintain at least 100 mm of clearance from the wall around all ventilation grilles to allow hot exhaust air to escape freely.
Drainage Clearance: Check the internal condensate drain channel during routine cleaning to ensure it remains clear of loose packaging labels, plastic film, and food crumbs.
Electrical Safety: Never wash down the workbench freezer with a commercial pre-rinse hose or high-pressure spray gun, and ensure water does not enter the digital controller or rear ventilation louvres.
The Thermaster TS1200BT is engineered for commercial prep lines, cafe counters, and underbench cookline spaces:
Standard 10A Electrical Connection: The workbench freezer draws 520W on standard single-phase 240V power and comes fitted with a standard Australian 10 Amp plug. Connect directly into a dedicated commercial wall outlet. Avoid the use of domestic extension leads or double adaptors.
Solid Floor Positioning & Stability: Position the 85 kg unit (exceeding 200 kg when fully loaded) on a flat, level, and solid commercial floor. Once rolled into place, ensure the castors sit evenly to prevent cabinet rocking and ensure both doors seal squarely.
Mandatory 100 mm Wall Ventilation Clearance: A minimum 100 mm wall clearance is strictly required around the ventilation louvres to ensure adequate heat dissipation from the compressor compartment. Restricting this airflow will reduce cooling performance, increase electricity consumption, and risk premature compressor failure.
Thermal Separation & Direct Heat: While rated for 32°C ambient conditions, avoid positioning the workbench freezer directly adjacent to intense heat-generating cooking equipment (such as deep fryers, open charbroilers, or high-temperature ranges) without a thermal heat barrier. Radiant heat warms the cabinet exterior and forces the refrigeration system to cycle continuously.
Pre-Freezing Protocol (Standard 3.2.2 Compliance): In accordance with Australian Commercial Food Safety Standards, underbench freezers are holding units designed to maintain pre-frozen product temperatures (-18°C to -22°C).All meats, seafood, chips, and ingredients must be pre-frozen below -18°C before loading into the cabinet. Never use the cabinet to freeze down hot, warm, or room-temperature foods.
Standard commercial road freight delivery is available Australia-wide to commercial business addresses with level ground access or loading docks. Due to the 85 kg net weight and commercial crating of this stainless steel workbench freezer, tail-lift delivery or a commercial loading dock with pallet handling equipment is recommended. For deliveries to residential or non-commercial addresses, please contact our friendly commercial sales team prior to ordering to obtain a customised courier quote and confirm delivery logistics.
Can I plug this double door workbench freezer into a standard Australian 10 Amp power point?
Yes. The Thermaster TS1200BT draws 520W on standard single-phase 240V power and comes fitted with a standard Australian 10 Amp plug. It connects straight into standard commercial wall sockets with no specialized electrical wiring required.
What is the difference between the TS1200TN and TS1200BT models?
The TS1200TN is a commercial workbench refrigerator operating between -2°C and +8°C for fresh ingredients. The TS1200BT is a commercial workbench freezer operating between -18°C and -22°C for frozen food storage, featuring higher wattage (520W) and an integrated heated door frame to eliminate frame frost and condensation.
Why does this freezer have a heated door frame?
Because the cabinet runs at sub-zero temperatures (-18°C to -22°C), contact with humid kitchen air causes condensation and frost around the door perimeter. The heated frame prevents this moisture accumulation, ensuring the magnetic rubber gaskets seal tightly and doors do not freeze shut.
Why is 100 mm of wall clearance required?
Commercial refrigeration compressors generate heat while extracting warm air from the cabinet interior. Maintaining at least 100 mm of clearance from the rear and side ventilation louvres allows this heat to dissipate efficiently into the room. Blocking these vents causes the compressor to overheat, reducing cooling performance and voiding the warranty.
Can I use the stainless steel top as a direct food preparation surface?
Yes. The solid stainless steel worktop is reinforced for commercial food preparation, allowing staff to place chopping boards, assemble orders, or mount benchtop appliances like slicers or vacuum sealers directly on top.
How do I qualify for the extended 2+2 Year Warranty?
The unit comes standard with a 2 Years Commercial Parts and Labour warranty. By registering your product online with the manufacturer within 14 days of the invoice date, you receive an additional 2 Years of Parts-Only warranty coverage, securing four total years of manufacturer protection.
N.B Image is for illustrative purposes only. Specifications are subject to change without notice.