Exquisite
Exquisite MV150 QCPP Approved Commercial Vaccine Fridge (148L)
Maintain cold-chain integrity, eliminate temperature breaches, and secure regulatory accreditation with the Exquisite MV400 400L Commercial Upright Glass Door Vaccine Refrigerator. Purpose-engineered for Australian medical centres, general practices (GPs), community pharmacies, hospital wards, dental clinics, pathology laboratories, and veterinary facilities, this high-capacity 595 mm wide upright biomedical refrigerator delivers precise holding across the strict +2°C to +8°C pharmaceutical range.
Storing biologicals, insulins, injectables, and vaccines requires adherence to the National Vaccine Storage Guidelines: Strive for 5. The Exquisite MV400 is fully QCPP (Quality Care Pharmacy Program) approved, meeting strict thermal performance benchmarks to ensure compliance with Australian regulatory inspections and professional audits.
Manual temperature recording introduces compliance risks and takes up valuable clinical staff time. The MV400 comes standard with an included temperature data logger, allowing practice managers to download and archive temperature histories via USB to satisfy cold-chain audit requirements. Operating alongside an intuitive digital controller with external LED display, the system continuously tracks internal air temperature. The controller is equipped with a battery backup circuit (battery supplied separately), ensuring alarms and digital temperature tracking continue to monitor your stock during localized power disruptions.
Standard static bar fridges suffer from hot spots and frozen base zones that can destroy sensitive serums. The MV400 features a dynamic fan-forced cooling system, distributing conditioned air evenly across all storage tiers to maintain a uniform +2°C to +8°C profile in ambient room temperatures ranging from +16°C to +32°C. Its automatic defrost cycle melts coil frost accumulation automatically, ensuring uninterrupted cooling and consistent airflow without requiring manual stock relocation.
Inventory visibility helps reduce door-open duration during busy vaccination clinics. The cabinet features a double-glazed heated/tempered glass door that resists external condensation while showcasing stocked supplies under energy-efficient internal LED lighting. The interior includes eight heavy-duty plastic-coated steel shelves, providing ample, hygienic tiered storage to segregate paediatric vaccines, travel doses, flu inoculations, and critical biological supplies.
Designed for quiet integration into treatment rooms, consultation suites, and dispensing areas, the MV400 runs at a quiet maximum noise level of 65 dB. Utilizing an energy-efficient 260W power rating (2.42 kWh/24hr consumption on 220–240V 50–60Hz supply), the unit comes factory-fitted with a standard Australian 10 Amp 3-pin plug and lead. Adjustable front levelling feet ensure stable positioning on clinic floors. The unit is supported by a comprehensive 24 Months Parts and Labour Warranty across Australia.
QCPP Approved: Fully compliant with Pharmacy Guild of Australia standards and the Strive for 5 national guidelines.
400L Usable Capacity (408L Gross): Generous volume holds seasonal flu clinics, childhood immunization reserves, and specialty medications.
Temperature Data Logger Included: Simplifies HACCP and QCPP audit logging with downloadable temperature verification records.
Stable +2°C to +8°C Thermal Control: Dynamic fan-forced air circulation eliminates temperature stratification and hot spots.
Battery Backup Controller Ready: Protects temperature readout and alert systems during mains power interruptions (battery sold separately).
Double-Glazed Glass Door: Minimises thermal transfer while providing instant stock visibility to reduce door-opening times.
8 Plastic-Coated Steel Shelves: Hygienic, corrosion-resistant wire shelves adjust to fit varied carton, vial, and box heights.
Integrated LED Interior Lighting: Clear, low-heat illumination makes reading prescription packaging fast and accurate.
Quiet 65 dB Sound Profile: Suitable for installation near patient consulting rooms and pharmacy dispensing counters.
Energy-Efficient 260W Power Draw: Consumes just 2.42 kWh per 24 hours, keeping clinical running costs low.
Standard Australian 10A Plug: Single-phase 240V plug-and-play design requires no hardwired electrical work.
24 Months Parts & Labour Warranty: Comprehensive warranty protection supported Australia-wide.
| Feature | Specification Details |
| Model Code / SKU | MV400 |
| Brand / Series | Exquisite Biomedical & Vaccine Storage Series |
| Product Type | Commercial Upright Glass Door Medical Vaccine Refrigerator |
| Gross / Net Usable Volume | 408 Litres Gross / 400 Litres Net Storage Capacity |
| Temperature Control Range | +2°C to +8°C (Factory Set for Vaccine Holding) |
| Ambient Temperature Rating | Rated for +16°C to +32°C Ambient Room Conditions |
| Compliance & Accreditations | QCPP (Quality Care Pharmacy Program) Approved |
| Data Logging System | Temperature Data Logger Included as Standard |
| Cooling & Airflow System | Dynamic Fan-Forced Air Circulation |
| Defrost System | Fully Automatic Defrost System |
| Controller Type | Digital Thermostat with LED Display & Battery Backup Capability |
| Door Construction | Heavy-Duty Double-Glazed Safety Glass Door |
| Internal Shelving | 8 x Adjustable Plastic-Coated Steel Wire Shelves |
| Cabinet Finish | Clean Medical White External and Internal Finish |
| Internal Lighting | High-Visibility, Low-Heat Internal LED Strip Light |
| Acoustic Noise Level | Maximum Noise Rating: ≤ 65 dB |
| Refrigerant Type | R134a |
| Energy Consumption | 2.42 kWh / 24 Hours |
| Electrical Power | 220–240V / 50–60Hz / Single Phase (260W / 1.7A / Standard AU 10A Plug) |
| External Dimensions | 1845(H) x 595(W) x 695(D) mm |
| Leveling Hardware | Front Adjustable Levelling Feet |
| Warranty Protection | 24 Months Commercial Parts & Labour Warranty |
To safeguard vaccine integrity, maintain hygiene standards, and uphold clinical accreditation:
Daily Minimum/Maximum Temperature Recording: Check and log the digital controller’s minimum, maximum, and current temperatures twice daily in accordance with Strive for 5 protocols.
Data Logger Downloads: Periodically download the records from the included temperature data logger to your practice management computer or cloud archive to maintain compliance files for QCPP audits.
Internal Cabinet Sanitisation: Clean internal white lining and plastic-coated shelves monthly using warm water and an approved hospital-grade, non-abrasive disinfectant. Discard any cracked or damaged packaging before it soils shelf surfaces.
Door Gasket Inspection: Wipe the magnetic door seals with a soft, damp cloth weekly. Ensure seals remain pliable and clear of dust to guarantee an airtight thermal barrier.
Condenser Airflow & Cleaning: Inspect the rear/lower ventilation louvres every 30 to 60 days. Clear away settled dust and lint using a soft brush attachment on a vacuum cleaner to prevent compressor strain and maintain temperature stability during hot summer conditions.
Battery Backup Maintenance: Check the battery status on the controller every six months and replace backup cells promptly to ensure continued monitoring during power outages.
The Exquisite MV400 is engineered for clinical treatment rooms, dispensaries, and laboratory prep areas:
Dedicated 10A Electrical Connection: Plug the unit directly into an independent, dedicated Australian 240V 10A wall outlet. In clinical environments, connect the refrigerator to an essential services circuit or back-up generator circuit where available. Never use domestic power boards, extension leads, or double adaptors.
Ventilation Clearances: Maintain at least 100 mm of clear airspace at the rear, sides, and top of the unit to ensure the refrigeration circuit can disperse heat effectively, especially when operating up to its maximum +32°C ambient rating.
Draft & Sunlight Separation: Avoid positioning the refrigerator directly opposite unshaded exterior windows, beneath direct heat lamps, or directly in line with split-system air conditioning drafts that could induce thermal stress on the glass door.
Shelf Airflow Protocols: When loading vaccines, keep carton stock within the wire boundaries of the 8 shelves and leave space around the internal fans. Never place stock flush against the back wall or pile boxes so tightly that internal fan-forced air distribution is restricted.
Cabinet Levelling: Use the front adjustable levelling feet to ensure the refrigerator sits upright with a slight backward tilt, ensuring the door swings shut reliably after staff retrieve supplies.
Standard commercial road freight delivery is available Australia-wide to commercial medical practices, pharmacies, hospitals, and clinical facilities with level ground access or loading bays. Due to the 1845 mm height, glass door construction, and sensitive refrigeration electronics, delivery via a hydraulic tail-lift truck or to a commercial loading dock with pallet handling equipment is standard. For deliveries to residential, home-based clinic, or non-commercial addresses, please contact our friendly commercial sales team prior to placing your order to obtain a customised courier quote and confirm delivery logistics.
Is the Exquisite MV400 compliant with Australian pharmacy regulations?
Yes. The MV400 is QCPP (Quality Care Pharmacy Program) approved and adheres to the National Vaccine Storage Guidelines: Strive for 5, making it fully accredited for medical centres, general practices, and retail pharmacies across Australia.
Is a data logger included with the unit?
Yes. The unit comes complete with an included temperature data logger, allowing practice managers to track, store, and export temperature history for regulatory compliance and audit verification.
How does the controller battery backup work?
The digital controller features a battery backup circuit that powers the digital temperature readout and internal monitoring functions during a mains power outage. Please note that the backup battery itself is supplied separately and should be installed upon initial clinic commissioning.
Can this medical fridge plug into a standard Australian power point?
Yes. The MV400 draws 260W (1.7A) on single-phase 220–240V power and comes factory-fitted with a standard Australian 10 Amp 3-pin plug and lead.
How many shelves are included, and are they adjustable?
The unit is supplied with eight plastic-coated steel wire shelves that can be adjusted at various height increments to accommodate different vial, syringe, and vaccine box dimensions.
Does this unit require manual defrosting?
No. The MV400 uses dynamic fan-forced cooling with an automated defrost cycle that melts any frost accumulation without interrupting the safe +2°C to +8°C holding temperature.
What warranty is included with the Exquisite MV400?
The unit is backed by a comprehensive 24 Months (2 Years) Commercial Parts and Labour Warranty across Australia.
N.B Images are for illustrative purposes only. Specifications are subject to change without notice.
Maintain cold-chain integrity, eliminate temperature breaches, and secure regulatory accreditation with the Exquisite MV400 400L Commercial Upright Glass Door Vaccine Refrigerator. Purpose-engineered for Australian medical centres, general practices (GPs), community pharmacies, hospital wards, dental clinics, pathology laboratories, and veterinary facilities, this high-capacity 595 mm wide upright biomedical refrigerator delivers precise holding across the strict +2°C to +8°C pharmaceutical range.
Storing biologicals, insulins, injectables, and vaccines requires adherence to the National Vaccine Storage Guidelines: Strive for 5. The Exquisite MV400 is fully QCPP (Quality Care Pharmacy Program) approved, meeting strict thermal performance benchmarks to ensure compliance with Australian regulatory inspections and professional audits.
Manual temperature recording introduces compliance risks and takes up valuable clinical staff time. The MV400 comes standard with an included temperature data logger, allowing practice managers to download and archive temperature histories via USB to satisfy cold-chain audit requirements. Operating alongside an intuitive digital controller with external LED display, the system continuously tracks internal air temperature. The controller is equipped with a battery backup circuit (battery supplied separately), ensuring alarms and digital temperature tracking continue to monitor your stock during localized power disruptions.
Standard static bar fridges suffer from hot spots and frozen base zones that can destroy sensitive serums. The MV400 features a dynamic fan-forced cooling system, distributing conditioned air evenly across all storage tiers to maintain a uniform +2°C to +8°C profile in ambient room temperatures ranging from +16°C to +32°C. Its automatic defrost cycle melts coil frost accumulation automatically, ensuring uninterrupted cooling and consistent airflow without requiring manual stock relocation.
Inventory visibility helps reduce door-open duration during busy vaccination clinics. The cabinet features a double-glazed heated/tempered glass door that resists external condensation while showcasing stocked supplies under energy-efficient internal LED lighting. The interior includes eight heavy-duty plastic-coated steel shelves, providing ample, hygienic tiered storage to segregate paediatric vaccines, travel doses, flu inoculations, and critical biological supplies.
Designed for quiet integration into treatment rooms, consultation suites, and dispensing areas, the MV400 runs at a quiet maximum noise level of 65 dB. Utilizing an energy-efficient 260W power rating (2.42 kWh/24hr consumption on 220–240V 50–60Hz supply), the unit comes factory-fitted with a standard Australian 10 Amp 3-pin plug and lead. Adjustable front levelling feet ensure stable positioning on clinic floors. The unit is supported by a comprehensive 24 Months Parts and Labour Warranty across Australia.
QCPP Approved: Fully compliant with Pharmacy Guild of Australia standards and the Strive for 5 national guidelines.
400L Usable Capacity (408L Gross): Generous volume holds seasonal flu clinics, childhood immunization reserves, and specialty medications.
Temperature Data Logger Included: Simplifies HACCP and QCPP audit logging with downloadable temperature verification records.
Stable +2°C to +8°C Thermal Control: Dynamic fan-forced air circulation eliminates temperature stratification and hot spots.
Battery Backup Controller Ready: Protects temperature readout and alert systems during mains power interruptions (battery sold separately).
Double-Glazed Glass Door: Minimises thermal transfer while providing instant stock visibility to reduce door-opening times.
8 Plastic-Coated Steel Shelves: Hygienic, corrosion-resistant wire shelves adjust to fit varied carton, vial, and box heights.
Integrated LED Interior Lighting: Clear, low-heat illumination makes reading prescription packaging fast and accurate.
Quiet 65 dB Sound Profile: Suitable for installation near patient consulting rooms and pharmacy dispensing counters.
Energy-Efficient 260W Power Draw: Consumes just 2.42 kWh per 24 hours, keeping clinical running costs low.
Standard Australian 10A Plug: Single-phase 240V plug-and-play design requires no hardwired electrical work.
24 Months Parts & Labour Warranty: Comprehensive warranty protection supported Australia-wide.
| Feature | Specification Details |
| Model Code / SKU | MV400 |
| Brand / Series | Exquisite Biomedical & Vaccine Storage Series |
| Product Type | Commercial Upright Glass Door Medical Vaccine Refrigerator |
| Gross / Net Usable Volume | 408 Litres Gross / 400 Litres Net Storage Capacity |
| Temperature Control Range | +2°C to +8°C (Factory Set for Vaccine Holding) |
| Ambient Temperature Rating | Rated for +16°C to +32°C Ambient Room Conditions |
| Compliance & Accreditations | QCPP (Quality Care Pharmacy Program) Approved |
| Data Logging System | Temperature Data Logger Included as Standard |
| Cooling & Airflow System | Dynamic Fan-Forced Air Circulation |
| Defrost System | Fully Automatic Defrost System |
| Controller Type | Digital Thermostat with LED Display & Battery Backup Capability |
| Door Construction | Heavy-Duty Double-Glazed Safety Glass Door |
| Internal Shelving | 8 x Adjustable Plastic-Coated Steel Wire Shelves |
| Cabinet Finish | Clean Medical White External and Internal Finish |
| Internal Lighting | High-Visibility, Low-Heat Internal LED Strip Light |
| Acoustic Noise Level | Maximum Noise Rating: ≤ 65 dB |
| Refrigerant Type | R134a |
| Energy Consumption | 2.42 kWh / 24 Hours |
| Electrical Power | 220–240V / 50–60Hz / Single Phase (260W / 1.7A / Standard AU 10A Plug) |
| External Dimensions | 1845(H) x 595(W) x 695(D) mm |
| Leveling Hardware | Front Adjustable Levelling Feet |
| Warranty Protection | 24 Months Commercial Parts & Labour Warranty |
To safeguard vaccine integrity, maintain hygiene standards, and uphold clinical accreditation:
Daily Minimum/Maximum Temperature Recording: Check and log the digital controller’s minimum, maximum, and current temperatures twice daily in accordance with Strive for 5 protocols.
Data Logger Downloads: Periodically download the records from the included temperature data logger to your practice management computer or cloud archive to maintain compliance files for QCPP audits.
Internal Cabinet Sanitisation: Clean internal white lining and plastic-coated shelves monthly using warm water and an approved hospital-grade, non-abrasive disinfectant. Discard any cracked or damaged packaging before it soils shelf surfaces.
Door Gasket Inspection: Wipe the magnetic door seals with a soft, damp cloth weekly. Ensure seals remain pliable and clear of dust to guarantee an airtight thermal barrier.
Condenser Airflow & Cleaning: Inspect the rear/lower ventilation louvres every 30 to 60 days. Clear away settled dust and lint using a soft brush attachment on a vacuum cleaner to prevent compressor strain and maintain temperature stability during hot summer conditions.
Battery Backup Maintenance: Check the battery status on the controller every six months and replace backup cells promptly to ensure continued monitoring during power outages.
The Exquisite MV400 is engineered for clinical treatment rooms, dispensaries, and laboratory prep areas:
Dedicated 10A Electrical Connection: Plug the unit directly into an independent, dedicated Australian 240V 10A wall outlet. In clinical environments, connect the refrigerator to an essential services circuit or back-up generator circuit where available. Never use domestic power boards, extension leads, or double adaptors.
Ventilation Clearances: Maintain at least 100 mm of clear airspace at the rear, sides, and top of the unit to ensure the refrigeration circuit can disperse heat effectively, especially when operating up to its maximum +32°C ambient rating.
Draft & Sunlight Separation: Avoid positioning the refrigerator directly opposite unshaded exterior windows, beneath direct heat lamps, or directly in line with split-system air conditioning drafts that could induce thermal stress on the glass door.
Shelf Airflow Protocols: When loading vaccines, keep carton stock within the wire boundaries of the 8 shelves and leave space around the internal fans. Never place stock flush against the back wall or pile boxes so tightly that internal fan-forced air distribution is restricted.
Cabinet Levelling: Use the front adjustable levelling feet to ensure the refrigerator sits upright with a slight backward tilt, ensuring the door swings shut reliably after staff retrieve supplies.
Standard commercial road freight delivery is available Australia-wide to commercial medical practices, pharmacies, hospitals, and clinical facilities with level ground access or loading bays. Due to the 1845 mm height, glass door construction, and sensitive refrigeration electronics, delivery via a hydraulic tail-lift truck or to a commercial loading dock with pallet handling equipment is standard. For deliveries to residential, home-based clinic, or non-commercial addresses, please contact our friendly commercial sales team prior to placing your order to obtain a customised courier quote and confirm delivery logistics.
Is the Exquisite MV400 compliant with Australian pharmacy regulations?
Yes. The MV400 is QCPP (Quality Care Pharmacy Program) approved and adheres to the National Vaccine Storage Guidelines: Strive for 5, making it fully accredited for medical centres, general practices, and retail pharmacies across Australia.
Is a data logger included with the unit?
Yes. The unit comes complete with an included temperature data logger, allowing practice managers to track, store, and export temperature history for regulatory compliance and audit verification.
How does the controller battery backup work?
The digital controller features a battery backup circuit that powers the digital temperature readout and internal monitoring functions during a mains power outage. Please note that the backup battery itself is supplied separately and should be installed upon initial clinic commissioning.
Can this medical fridge plug into a standard Australian power point?
Yes. The MV400 draws 260W (1.7A) on single-phase 220–240V power and comes factory-fitted with a standard Australian 10 Amp 3-pin plug and lead.
How many shelves are included, and are they adjustable?
The unit is supplied with eight plastic-coated steel wire shelves that can be adjusted at various height increments to accommodate different vial, syringe, and vaccine box dimensions.
Does this unit require manual defrosting?
No. The MV400 uses dynamic fan-forced cooling with an automated defrost cycle that melts any frost accumulation without interrupting the safe +2°C to +8°C holding temperature.
What warranty is included with the Exquisite MV400?
The unit is backed by a comprehensive 24 Months (2 Years) Commercial Parts and Labour Warranty across Australia.
N.B Images are for illustrative purposes only. Specifications are subject to change without notice.